FLUIDISTOR – Gas Flowmeter GD 500 EX – external pipe thread

GD500Ex

The GD 500 Ex is used for small nominal sizes (DN 15 – DN 25) and low flow rates.

Oscillating measuring principle without moving parts – no wearing parts
High accuracy (± 1.5% of the measured value)
Measuring range from 1: 100

TECHNICAL DATA

Description

Nominal size (NW)

DN 15 - DN 25

Process connection

external pipe thread
R 1/2” (DN 15)
G 1” (DN 25)

Pressure range

0,5 bar, 10 bar, 16 bar, 40 bar

Temperature medium

NON ATEX: -20 to +120°C
ATEX: up to max. +80°C

Ambient temperature

NON ATEX: -20 to +120°C
ATEX: -20 to +45 °C

Measuring head & labyrinth

Material stainless steel 1.4571 (V4A), aluminum (AL)

Sensor

Material platinum

Protection class

IP 65

Output A:
(standard)

Native pulse output: pulse 24 V, DC, max. 200 Hz (pulse width 1 - 2 ms)
status output for sensor break detection: 24 V, DC
(for connection to external Flow Computer GDR 150x)

Output B
(with integrated calculator)

Pulse output: pulse 24 V, DC, 1 pulse=0.01, 0. 1, 1, 10 or 100 m³
current interface: (0)4 - 20 mA = 0 - x Nm³/h , status output for sensor break detection: 24 V, DC
standard: DIN 1343, DIN 6358, DIN ISO 2533, DIN 102/ISO 1-1975 fixed value temperature: -50 °C to 200°C fixed value absolute pressure: -0,8 bar to 100 bar bar

ATEX certification

Ex II 1 / 2 G Ex ia / e mb IIC T4 Ga / Gb, EG certificate no: TPS 13 ATEX 14689 003 X
(certificate no. EX5 13 07 14689 003)

Ball valve

OPTION AVF
ball valve (blocking valve) for GD 300 with flange removal/installation of the platinum wire sensor without emptying the system

Nominal size (NW)

DN 15 - DN 25

Process connection

external pipe thread
R 1/2” (DN 15)
G 1” (DN 25)

Pressure range

0,5 bar, 10 bar, 16 bar, 40 bar

Temperature medium

NON ATEX: -20 to +120°C
ATEX: -20 to +45 °C

Ambient temperature

NON ATEX: -20 to +120°C
ATEX: -20 to +45 °C

Measuring head & labyrinth

Material stainless steel 1.4571 (V4A), aluminum (AL)

Sensor

Material platinum

Protection class

IP 65

Output A:
(standard)

Native pulse output: pulse 24 V, DC, max. 200 Hz (pulse width 1 - 2 ms) status output for sensor break detection: 24 V, DC (for connection to external Flow Computer GDR 150x)

Output B
(with integrated calculator)

Pulse output: pulse 24 V, DC, 1 pulse=0.01, 0. 1, 1, 10 or 100 m³ current interface: (0)4 - 20 mA = 0 - x Nm³/h , status output for sensor break detection: 24 V, DC standard: DIN 1343, DIN 6358, DIN ISO 2533, DIN 102/ISO 1-1975 fixed value temperature: -50 °C to 200°C fixed value absolute pressure: -0,8 bar to 100 bar

ATEX certification

Ex II 1 / 2 G Ex ia / e mb IIC T4 Ga / Gb, EG certificate no: TPS 13 ATEX 14689 003 X
(certificate no. EX5 13 07 14689 003)

Ball valve

OPTION AVF ball valve (blocking valve) for GD 300 with flange removal/installation of the platinum wire sensor without emptying the system

Measurement range

NW Inches Measurement range
15
R 1/2"
0,06 - 22 m3/h
25
G 1"
0,06 - 22 m3/h

Dimensions & Weights

NW weight KG (AL) weight KG (V4)
15

4

8

25

4

8

Related LINKS

Download

ankara escort çankaya escort
Translate »
Esters-Logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.